A1C to eAG Calculator (Estimated Average Glucose)
Translate laboratory NGSP HbA1c (%) into estimated average glucose (eAG) in both mg/dL and mmol/L using the Nathan et al. (2008) ADAG linear regression equation.
How to Use This Calculator
- Choose whether you are converting from HbA1c (%) to eAG or from average glucose (eAG) to estimated A1C.
- Enter your laboratory A1C percentage (for example, 7.0%) or average glucose value.
- Review the calculated eAG in both mg/dL and mmol/L alongside the unrounded reference equation output.
Formula and Units
Equation Summary: eAG (mg/dL) = 28.7 × A1C (%) − 46.7; eAG (mmol/L) = eAG (mg/dL) / 18.0182
Published by the A1C-Derived Average Glucose (ADAG) study group (Nathan et al., Diabetes Care 2008): eAG (mg/dL) = 28.7 × A1C (%) − 46.7. Inverse calculation: A1C (%) = (eAG (mg/dL) + 46.7) / 28.7. Conversion to molar glucose units divides mg/dL by 18.0182.
Supported Units: % (NGSP), mg/dL, mmol/L
Worked Example
For an HbA1c of 7.0%: eAG = 28.7 × 7.0 − 46.7 = 200.9 − 46.7 = 154.2 mg/dL (rounded to 154 mg/dL, or 154.2 / 18.0182 = 8.56 mmol/L, displayed as 8.6 mmol/L).
Understanding the Result
Estimated average glucose expresses a 2-to-3-month laboratory HbA1c value in the same daily units (mg/dL or mmol/L) shown on home blood glucose meters and continuous glucose monitors.
Limitations
- The ADAG regression represents a population average with prediction intervals; two people with the same A1C can have different true mean glucose values.
- Conditions that alter red blood cell lifespan (anemia, hemoglobinopathies, recent transfusion, advanced kidney disease, pregnancy) can cause laboratory A1C to diverge from mean glucose.
- Educational reference only; individualized glycemic targets depend on age, pregnancy status, hypoglycemia risk, and clinician guidance.
Related Tools
HbA1c Unit Converter (mmol/mol ↔ %)
Convert laboratory HbA1c results between IFCC standard units (mmol/mol, used in the UK, Europe, and Australia) and NGSP/DCCT percentage units (%, used in the US and Canada) using the published NGSP/IFCC master equation.
GMI Calculator (Glucose Management Indicator)
Calculate your Glucose Management Indicator (GMI) in both NGSP-aligned % and IFCC-equivalent mmol/mol from your continuous glucose monitor (CGM) mean glucose using the published Bergenstal et al. (2018) formula.
Blood Glucose Unit Converter (mg/dL ↔ mmol/L)
Convert blood glucose values between milligrams per deciliter (mg/dL) and millimoles per liter (mmol/L) using the exact molar mass factor of glucose (18.0182).
Frequently Asked Questions
Why is my eAG higher or lower than my morning fasting fingerstick?
Fasting fingersticks capture a single moment (typically the lowest overnight baseline), whereas eAG reflects 24-hour glucose exposure including post-meal peaks.
Does A1C to eAG apply to IFCC mmol/mol results?
If your lab reports HbA1c in mmol/mol, use the HbA1c Unit Converter first to convert mmol/mol to NGSP %, or view both inside our HbA1c converter.
Sources and Review Information
- [S9] Nathan DM, Kuenen J, Borg R, et al. Translating the A1C assay into estimated average glucose values (ADAG Study). Diabetes Care. 2008;31(8):1473-1478. Reference Source
- [S10] NGSP / IFCC Master Equation: Hoelzel W, Weykamp C, Jeppsson JO, et al. IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes. Clin Chem. 2004;50(1):166-174. Reference Source
Prepared by: GlucoBP Editorial & Engineering Team · Verification status: Formula verified against published reference; clinical review pending · Last updated: 2026-11-15