HOMA-IR Calculator (Fasting Insulin & Glucose Index)
Compute the Homeostatic Model Assessment for Insulin Resistance (HOMA-IR) from a paired morning fasting blood draw using the published Matthews et al. (1985) equation.
How to Use This Calculator
- Select whether your fasting glucose lab result is in mg/dL or mmol/L.
- Enter your fasting insulin in µIU/mL ( numerically equivalent to mU/L) and fasting glucose.
- Review the calculated HOMA-IR index and laboratory assay caveats.
Formula and Units
Equation Summary: HOMA-IR = (Fasting Insulin [µIU/mL] × Fasting Glucose [mg/dL]) / 405
Matthews et al. (Diabetologia 1985): HOMA-IR = (Fasting Insulin [µIU/mL] × Fasting Glucose [mg/dL]) / 405. In molar glucose units: HOMA-IR = (Fasting Insulin [µIU/mL] × Fasting Glucose [mmol/L]) / 22.5.
Supported Units: µIU/mL (or mU/L), mg/dL, mmol/L
Worked Example
For fasting insulin = 10 µIU/mL and fasting glucose = 95 mg/dL: HOMA-IR = (10 × 95) / 405 = 950 / 405 = 2.35.
Understanding the Result
HOMA-IR is a research and clinical surrogate estimate of hepatic insulin sensitivity derived from basal fasting glucose-insulin feedback.
Limitations
- Both values must come from a single fasting venous blood draw (typically 8–12 hours fasted).
- Insulin immunoassays are not universally standardized across laboratories, and population cutoffs vary by ethnicity, age, and assay platform.
- HOMA-IR is difficult to interpret in individuals taking exogenous insulin or insulin secretagogues.
Related Tools
TyG Index Calculator (Triglyceride-Glucose Index)
Calculate the logarithmic Triglyceride-Glucose (TyG) index from fasting triglycerides and fasting glucose, with automatic unit conversion when labs are entered in mmol/L.
Blood Glucose Unit Converter (mg/dL ↔ mmol/L)
Convert blood glucose values between milligrams per deciliter (mg/dL) and millimoles per liter (mmol/L) using the exact molar mass factor of glucose (18.0182).
BMI Calculator (Metric & Imperial)
Calculate adult Body Mass Index (BMI) in kg/m² using either metric (kg and cm) or imperial (pounds, feet, and inches) measurements.
Frequently Asked Questions
Why does HOMA-IR require a fasting sample?
Post-meal insulin rises physiologicaly by several fold; entering a non-fasting value invalidates the basal steady-state equation.
Sources and Review Information
- [HOMA-1985] Matthews DR, Hosker JP, Rudenski AS, et al. Homeostasis model assessment: insulin resistance and beta-cell function from fasting plasma glucose and insulin concentrations in man. Diabetologia. 1985;28(7):412-419. Reference Source
Prepared by: GlucoBP Editorial & Engineering Team · Verification status: Formula verified against published reference; clinical review pending · Last updated: 2026-11-15